At a Glance

The following tables describe the T_ANA_OUT_BMX-type IODDT objects applicable to the BME AHO 0412, BMX AMO 0210, BMX AMO 0410 and BMX AMO 0802 analog output modules and the outputs of the BMX AMM 600 mixed module.

Value of the Output

The analog output measurement object is as follows.

Standard symbol

Type

Access

Meaning

Address

VALUE

INT

R

Analog output measurement.

%QWr.m.c.0

%Ir.m.c.ERR error bit

The %Ir.m.c.ERR error bit is as follows.

Standard symbol

Type

Access

Meaning

Address

CH_ERROR

BOOL

R

Error bit for analog channel.

%Ir.m.c.ERR

Value Forcing

The value forcing bit is as follows.

Standard symbol

Type

Access

Meaning

Address

FORCING_VALUE

INT

R

Forcing of the value.

%IWr.m.c.0

Channel forcing indicator.

The meaning of the forcing control bits of the channel (%IWr.m.c.1) is as follows.

Standard symbol

Type

Access

Meaning

Address

CHANNEL_FORCED

BOOL

R

Forcing of the channel.

%MWr.m.c.1.1

Explicit Exchange Execution Flag: EXCH_STS

The meaning of the exchange control bits of the channel EXCH_STS (%MWr.m.c.0) is as follows:

Standard symbol

Type

Access

Meaning

Address

STS_IN_PROGR

BOOL

R

Read channel status words in progress.

%MWr.m.c.0.0

CMD_IN_PROGR

BOOL

R

Command parameter exchange in progress.

%MWr.m.c.0.1

ADJ_IN_PROGR

BOOL

R

Adjustment parameter exchange in progress.

%MWr.m.c.0.2

Explicit Exchange Report: EXCH_RPT

The meaning of the EXCH_RPT (%MWr.m.c.1) report bits is as follows:

Standard symbol

Type

Access

Meaning

Address

STS_ERR

BOOL

R

Read error detected for channel status words.

%MWr.m.c.1.0

CMD_ERR

BOOL

R

Error detected during command parameter exchange.

%MWr.m.c.1.1

ADJ_ERR

BOOL

R

Error detected while exchanging adjustment parameters.

%MWr.m.c.1.2

RECONF_ERR

BOOL

R

Error detected while reconfiguring the channel.

%MWr.m.c.1.15

Standard Channel Status: CH_FLT

The following table explains the meaning of the CH_FLT (%MWr.m.c.2) status word bits. Reading is performed by a READ_STS (IODDT_VAR1).

Standard symbol

Type

Access

Meaning

Address

ACT_WIRE_FLT

BOOL

R

Actuator wire open or short.

%MWr.m.c.2.0

RANGE_FLT

BOOL

R

Range under/overflow detected error.

%MWr.m.c.2.1

SHORT_CIRCUIT

BOOL

R

Short-circuit.

%MWr.m.c.2.2

CAL_PRM_FLT

BOOL

R

Calibration parameters not configured.

%MWr.m.c.2.3

INTERNAL_FLT

BOOL

R

Inoperative channel.

%MWr.m.c.2.4

CONF_FLT

BOOL

R

Different hardware and software configurations.

%MWr.m.c.2.5

COM_FLT

BOOL

R

Problem detected communicating with the PLC.

%MWr.m.c.2.6

APPLI_FLT

BOOL

R

Application detected error (adjustment or configuration detected error).

%MWr.m.c.2.7

ALIGNED_CH

BOOL

R

Aligned channels.

%MWr.m.c.3.0

INT_CAL_FLT

BOOL

R

Calibration parameters not defined.

%MWr.m.c.3.2

INT_PS_FLT

BOOL

R

Internal power supply detected error.

%MWr.m.c.3.3

INT_SPI_FLT

BOOL

R

Serial link detected error.

%MWr.m.c.3.4

RANGE_UNF

BOOL

R

Range underflow.

%MWr.m.c.3.6

RANGE_OVF

BOOL

R

Range overflow.

%MWr.m.c.3.7

Command Control

The following table explains the meaning of the COMMAND_ORDER (%MWr.m.c.4) status word bit. Reading is performed by a READ_STS:

Standard symbol

Type

Access

Meaning

Address

FORCING_UNFORCING_ORDER

BOOL

R/W

Forcing/unforcing command.

%MWr.m.c.4.13

Parameters

The following table shows the meaning of the words %MWr.m.c.5 to %MWr.m.c.8. The requests used are those associated with the parameters (READ_PARAM and WRITE_PARAM).

Standard symbol

Type

Access

Meaning

Address

CMD_FORCING_VALUE

INT

R/W

Forcing value to be applied.

%MWr.m.c.5

FALLBACK

INT

R/W

Fallback value.

%MWr.m.c.7

ALIGNMENT

INT

R/W

Alignment value.

%MWr.m.c.8

NOTE: In order to force a channel, you have to use the WRITE_CMD (%MWr.m.c.5) instruction and set the %MWr.m.c.4.13 bit to 1.
NOTE: To unforce a channel and use it normally, you have to set the %MWr.m.c.4.13 bit to 0.